Super Retaining Wall

An L-shaped wall that uses the soil it holds to stay put. Twelve heights from 0.6 m to 3.0 m, drained and coupled at every joint; for taller cuts the segmental wall goes up to 9.15 m.

Features

Applications

What it prevents

Installation

  1. Check ground: Required ground strength from 30 kN/m² (H 600) to 110 kN/m² (H 2500).
  2. Foundation: Crushed stone, foundation concrete, 20 mm bedding mortar.
  3. Set & couple: Place units, bolt the flange couplings, fit draft strips at joints.
  4. Backfill: Filter behind the drain holes, then fill in layers over the heel.

Frequently asked questions

What is the Super Retaining Wall?

An L-shaped wall that uses the soil it holds to stay put. Twelve heights from 0.6 m to 3.0 m, drained and coupled at every joint; for taller cuts the segmental wall goes up to 9.15 m. It is made by Super Cement Articles (SCA), a precast and prestressed concrete manufacturer established in 1982 with six plants in Nashik (Maharashtra) and Unnao / Lucknow (Uttar Pradesh).

Where is the Super Retaining Wall used?

A river between the hills, Walls on both banks stop the monsoon river eating into the road and the fields above it. Holding a coastal road above the beach, A line of L-walls at the back of the beach keeps the sea-front road standing: rock armour at the toe breaks the waves, the retained fill carries two lanes and a promenade.

What sizes of Super Retaining Wall are available?

14 catalogue sizes, including H 600, H 800, H 1000, H 1200, H 1400, H 1600, H 1800, H 2000 and more. Every size is shown in 3D on the product page and in the SCA size range.

What problems does the Super Retaining Wall prevent?

Landslips & slope failure: The heel sits under the retained fill; its weight resists sliding and overturning. Water pressure behind the wall: ø75 drain holes with soil-stop filters relieve the build-up that topples walls. Cracked site-cast walls: Factory-cast, reinforced units checked for Fs ≥ 1.5 against sliding. Weeks of formwork: Set by crane, couple, backfill, the line rises in days.

How is the Super Retaining Wall installed?

1. Check ground, Required ground strength from 30 kN/m² (H 600) to 110 kN/m² (H 2500). 2. Foundation, Crushed stone, foundation concrete, 20 mm bedding mortar. 3. Set & couple, Place units, bolt the flange couplings, fit draft strips at joints. 4. Backfill, Filter behind the drain holes, then fill in layers over the heel.

Who manufactures the Super Retaining Wall in India?

Super Cement Articles (SCA), Nashik and Lucknow, 40+ years in precast, 3,50,000+ tonnes a year, BIS IS:12592 and ISO 9001 / 14001 / 45001 certified, designs to IS with Japanese precision in the detailing. Supplied pan-India.

How do I get a price for the Super Retaining Wall?

Send the size, quantity and site location through the enquiry form on the page (drawings and CAD files can be attached), call +91 98502 25049 (Nashik) or +91 97941 80000 (Lucknow), or email info@supercementarticles.in. SCA replies within one working day.